HPLC·¨²â¶¨Ë®²úÆ·Öа¢±½´ïßò¼°ÆäÖ÷Òª´úлÎï²ÐÁôµÄÑо¿

±¾ÎÄID£º16518 ×ÖÊý:10084,Ò³Êý:28

ÏÂÔØµØÖ· È«ÎÄÏÂÔØÁ´½Ó(³äÖµ:£¤128.00Ôª) 

ÂÛÎıàºÅ:SW080  ÂÛÎÄ×ÖÊý:10084,Ò³Êý:28

Õª Òª£º±¾ÎÄÖ÷Òª²ûÊöÁËÓ¦ÓøßЧҺÏàÉ«Æ×£¨HPLC£©·½·¨²â¶¨Ë®²úÆ·Öа¢±½´ïßò£¨ABZ£©¼°ÆäÁ½ÖÖÖ÷Òª´úлÎïí¿£¨ABZSO2£©¡¢ÑÇí¿£¨ABZSO£©²ÐÁôÁ¿µÄÑо¿¡£É«Æ×Ìõ¼þÊÇ£ºÉ«Æ×ÖùΪZORBAX-SB 5¦Ìm C18Öù£»Á÷¶¯ÏàÊÇËữÒÒëæ£ºË®(25:75£»v/v)£»¼×´¼-Á×ËỺ³åÒº£¨75©U25£»v/v£©£¬Á÷ËÙÊÇ1.0mL/min£¬ÖùÎÂÊÇ30¡æ£¬Ñ¡ÔñµÄ¼ì²â²¨³¤ÊÇ295.4nm¡£²ÉÓü״¼£ºÁ×ËỺ³åÒº=75£º25¶¨ÈÝϵÁбê×¼Òº£¬°¢±½´ïßò¡¢°¢±½´ïßòí¿¡¢°¢±½´ïßòÑÇí¿ÔÚ0.1¡«10¦Ìg/mL·¶Î§ÄÚÏßÐÔ¹ØÏµÁ¼ºÃ£¬¼Ó±êŨ¶ÈÔÚ100¦Ìg/kg¡«500¦Ìg/kgʱ£¬»ØÊÕÂÊ·Ö±ðABZSOΪ83%¡«95%£»ABZSO2Ϊ85%¡«97%£»ABZΪ70%¡«80%¡£Ñо¿½á¹ûÏÔʾ£¬¸Ã·½·¨µÄ×îµÍ¼ì²âÏÞ¡¢×¼È·¶ÈºÍ¾«ÃܶȾù·ûºÏ²ÐÁô¼ì²â·½·¨µÄÒªÇ󡣴˼ì²â·ÖÎö·½·¨´¦ÀíÑùÆ·¿ìËÙ¡¢¸ßЧ¡¢×¼È·£¬¿É×÷Ϊˮ²úÆ·Öа¢±½´ïßò¼°ÆäÖ÷Òª´úлÎïµÄÓÐЧ¼ì²â·½·¨¡£
¹Ø¼ü´Ê£ºË®²úÆ·¡¢¸ßЧҺÏàÉ«Æ×·¨¡¢°¢±½´ïßò¼°Æä´úлÎï

Determination of Albendazole and its metabolites in Aquatic products by HPLC
Abstract: The determination of Albendazole and its metabolites in aquatic products was established by using high performance liquid chromatography (Agilent-1100, USA) with a photodiode array detector detector (DAD, USA), a C18 column (ZORBAX-SB). The mobile phase was a mixture of acidified acetonitrile and water (25/75, v/v) and a mixture of methanol and phosphate buffer (75/25, v/v). 20 µl samples at room temperature injected onto the column through a 20 µl sample loop. Column temperature is 300C.The mobile phase rate was delivered at 1.0 ml/min. Detection wavelength: 295.4nm. In the range of 0. 1 - 10¦Ìg/ml, the results of Albendazole and its metabolite are linearly dependent. The mean extraction recoveries of Albendazole and its metabolites ranged from 80% to 90%. The method of determining the Albendazole and its metabolites in aquatic product was established by using reversed-phase HPLC, which had characters of simple and rapid operation, high yield and good reproducibility.

Keywords£ºAquatic products, high performance liquid chromatography, Albendazole and its metabolites

Ä¿  ¼
ÖÐÎÄÕªÒª I
Ó¢ÎÄÕªÒª II
Ŀ¼ III
1. Ð÷ÂÛ 1
 1.1  ǰÑÔ 1
 1.2 °¢±½´ïßò¼°ÆäÖ÷Òª´úлÎï¼ì²â¼¼ÊõµÄ¹úÄÚÍâ·¢Õ¹ÏÖ×´ 2
2. ʵÑ鲿·Ö 5
 2.1  ÊÔ¼ÁºÍ²ÄÁÏ 5
 2.2  ÒÇÆ÷É豸 5
 2.3  ʵÑé²Ù×÷·½·¨ 6
3. ½á¹ûÓëÌÖÂÛ 8
 3.1   ÑùƷǰ´¦ÀíÌõ¼þµÄÑ¡Ôñ 8
 3.2   É«Æ×Ìõ¼þµÄÑ¡Ôñ 8
 3.3   ¾«ÃܶȺÍ׼ȷ¶È 14
 3.4   ·½·¨µÄÁéÃô¶ÈºÍ¼ì²âÏÞ 19
4£®×ܽáÓëÕ¹Íû 20

ÖÂл 21
²Î¿¼ÎÄÏ× 22

Ïà¹ØÂÛÎÄ
ÉÏһƪ£ºÄ©¶ËΪôÈ»ùµÄС·Ö×Ó¼õË®¼ÁµÄºÏ³É.. ÏÂһƪ£ºµ°°×ÖÆÆ·ÖÐÈý¾ÛÇè°·¼°ÇèÄòËẬÁ¿..
ÍÆ¼öÂÛÎÄ ±¾×¨Òµ×îÐÂÂÛÎÄ
Tags£ºHPLC ²â¶¨ Ë®²úÆ· ¼°Æä Ö÷Òª ´úл ²ÐÁô Ñо¿ 2011-03-31 15:48:27¡¾·µ»Ø¶¥²¿¡¿

Ïà¹ØÀ¸Ä¿

½ÌÓý¹ÜÀíÂÛÎÄ
ººÓïÑÔÎÄѧ
ѧǰ½ÌÓýÂÛÎÄ
ÐÄÀíѧÂÛÎÄ
Сѧ½ÌÓýÂÛÎÄ
ÏÖ´ú½ÌÓý¼¼Êõ
ÊýѧÓëÓ¦ÓÃÊýѧ
Êýѧ½ÌÓýÂÛÎÄ
¹¤É̹ÜÀí
ÈËÁ¦×ÊÔ´¹ÜÀí
²ÆÎñ»á¼Æ
·¨ÂÉÂÛÎÄ
ÐÐÕþ¹ÜÀíÂÛÎÄ
ÎïÁ÷רҵÂÛÎÄ
µç×ÓÉÌÎñÂÛÎÄ
Àí¹¤¿ÆÂÛÎÄ
ÎïÀíѧÂÛÎÄ
ÏçÕòÆóÒµ¹ÜÀí
µçÊÓÖÆÆ¬¹ÜÀí
ÎÄ»¯²úÒµ¹ÜÀí
ÎïÒµ¹ÜÀíÂÛÎÄ
±ÏÒµÂÛÎÄÏÂÔØ
°ü×°¹¤³ÌÂÛÎÄ
Ó¡Ë¢¹¤³ÌÂÛÎÄ
¹¤Òµ¹¤³ÌÂÛÎÄ
ÐÅÏ¢¹ÜÀíÂÛÎÄ
ÉúÎ﹤³ÌÂÛÎÄ
ÖÆÒ©¹¤³ÌÂÛÎÄ
µç×ÓÐÅÏ¢¹¤³Ì
ͨÐŹ¤³ÌÂÛÎÄ
µçÆø¹¤³ÌÂÛÎÄ
ÐÅÏ¢¼ÆËã¿ÆÑ§
ҩѧרҵ±ÏÒµÂÛÎÄ


¹ØÓÚÎÒÃÇ | ÁªÏµ·½Ê½ | ÂÛÎÄ˵Ã÷ | ÍøÕ¾µØÍ¼ | Ãâ·Ñ»ñÈ¡ | ×êʯ»áÔ± | Ô­´´±ÏÒµÂÛÎÄ

 

ÂÛÎÄÌìÏÂÍøÌṩÂÛÎļì²â,ÂÛÎĽµÖØ,ÂÛÎÄ·¶ÎÄ,ÂÛÎÄÅŰæ,ÍøÕ¾ÓÀ¾ÃÓòÃûWWW.GEPUW.NET

±¾Õ¾²¿·ÖÎÄÕÂÀ´×ÔÍøÓÑͶ¸åÉÏ´«£¬Èç·¢ÏÖÇÖ·¸ÁËÄúµÄ°æÈ¨£¬ÇëÁªÏµÖ¸³ö£¬±¾Õ¾¼°Ê±È·Èϲ¢É¾³ý  E-mail: 893628136@qq.com

Copyright@ 2009-2022 GEPUW.NET ÂÛÎÄÌìÏÂÍø °æÈ¨ËùÓÐ